Eaton Wiring Devices SGF20W Duplex GFCI Receptacle, 125 VAC, 20 A, 2 Poles, 3 Wires, White

EATON SGF20W 20 AMP WHITE SELF TEST GFCI RECEPTACLE

GFCI Receptacles }

Eaton Wiring Devices SGF20W Duplex GFCI Receptacle, 125 VAC, 20 A, 2 Poles, 3 Wires, White

3473722 Product ID:3473722
Famous Supply
  • Dimensions: 4.2 in L x 1.68 in W x 1.27 in D
  • Enclosure: IP65
  • Frequency Rating: 60
  • Material: Thermoplastic
  • NEMA Rating: NEMA 5-20R
  • Series: SGF
  • Temperature Rating: -35 to 66 deg c
  • Terminal Type: Back/Side Wired
  • Type: Duplex
  • Voltage Rating: 125
  • Amperage Rating: 20
  • Number of Poles: 2
  • Number of Wires: 3
  • Color: White
Eaton's Arrow Hart line of self-test GFCI receptacles ensure electrical shock protection with periodical automatic testing. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. Self-Test GFCI receptacles are available in a number of grades including hospital, tamper resistant, non-tamper resistant and weather resistant, as well as a variety of colors including white, ivory, almond, light almond, black, brown, gray and red.
  • Features
  • Standards & Approvals
  • Includes
  • Application
If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced
Performs periodic self-tests to ensure integrity of GFCI protection
Visual trip indicator light gives quick notification of a tripped or end of life condition
Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards
Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
Tamper resistant shutters help prevent foreign objects from being inserted
Line side terminals are backed out and staked for fast installation
Horizontal test/reset button alignment provides larger unobstructed area
Test and reset buttons are color matched to provide superior aesthetics
Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
When downstream receptacles are wired from load side, a 20A feed through rating offers full protection
Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly
Tri-combo head terminal and mounting screws
Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations
Thermoplastic, polypropylene top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts material
#8-32 steel, brass plated, neutral screw nickel plated, ground screw green terminal and ground screws, 0.07 in thick steel terminal clamps
Withstands 2000 V per UL498 dielectric voltage
V2 rated UL94 flammability
Current interrupting at full-rated current, 0.025 sec class A trip time, Short circuit testing meets and exceeds 10 kA, maximum interrupting capacity of 20 A
#14 to 10 AWG terminal accommodation, Back Wire and Side Wire
cULus Listed to UL 498
UL 943
E60120
UL 508
CSA Certified
NOM Certified
Matching Thermoplastic Wallplate
Commercial, Industrial and Institutional