                        Intermittent Pilot Retrofit Kit
                        HONEYWELL Y8610U6006 Y-PACK CONTAINING: S8610U3009 & VR8304M W/ 1/2" X 3/4" INLET/ OUTLET, FLANGE KIT, LP CONVERSION KIT
                        
                        
                             Pilot Retrofit Systems 
                            
                            }
                            
Intermittent Pilot Retrofit Kit
                            
                                
                                    3068525
                                        MFG #: Y8610U6006
                                    Product ID:3068525
                                
                             
                            
                                
                                
                                
                                
                                    Famous Supply
                                
                                
                            
                         
                        
                        
                                
                                        - 
                                            Electrical Connections:
                                            
Quick Terminal
                                            
                                        
 
                                        - 
                                            Gas Type:
                                            
Liquid Propane/Natural Gas
                                            
                                        
 
                                        - 
                                            Prepurge Time:
                                            
30 s
                                            
                                        
 
                                        - 
                                            Pressure Rating:
                                            
1/2 psig
                                            
                                        
 
                                        - 
                                            Suitable For Use With:
                                            
Natural or LP Gas
                                            
                                        
 
                                        - 
                                            Capacity:
                                            
270000 btu/hr
                                            
                                        
 
                                        - 
                                            Voltage Rating:
                                            
24
                                            
                                        
 
                                        - 
                                            Amperage Rating:
                                            
2
                                            
                                        
 
                                        - 
                                            Control Voltage:
                                            
24
                                            
                                        
 
                                        - 
                                            Domestic/Import:
                                            
Import
                                            
                                        
 
                                
                            Intermittent Pilot Retrofit Kits save energy by converting atmospheric standing pilot systems to intermittent pilot. Typical applications are gas-fired atmospheric furnaces, boilers and heating appliances.
                         
                            
                     
                    
                 
                    
                        
                            
                                    - 
                                        Features
                                    
 
                                    - 
                                        Standards & Approvals
                                    
 
                                    - 
                                        Includes
                                    
 
                            
                            
                                    
                                        | Includes gas valves, ignition module, pilot burner hardware, ignition cable and wiring harness | 
| Provides 100 percent pilot gas shutoff if pilot fails to light; after 6 min delay, trial for ignition is repeated | 
| Ignition trail or delay sequence is repeated until the appliance lights or call for heat is removed | 
| 24 V control at 60 Hz | 
                                     
                                    
                                    
                                        
                        
                            | S8610U Intermittent Pilot Module, VR8304M3558 Furnace Gas Valve, 392431 Igniter-Sensor, 394800-30 Ignition Cable, 393691 Natural to LP Gas Conversion Kit, Wiring Harness, 393690-14 Straight Flange Kit (3/4 in), Reducer Adapters for Gas Control with VR8304M and Installation Hardware |