Little Giant 553500 EC-1 Automatic Condensate Removal Pump, 2.5 gph Flow Rate, 1/4 in Outlet, 33 ft Shutoff Head

LITTLE-GIANT 553500 EC-1 115V CONDENSATE PUMP ELECTRONIC FOR MINI SPLIT SYSTEMS

Condensate Pumps }

Little Giant 553500 EC-1 Automatic Condensate Removal Pump, 2.5 gph Flow Rate, 1/4 in Outlet, 33 ft Shutoff Head

3317592 Product ID:3317592
Famous Supply
  • Dimensions: 4.1 in L x 1.82 in W x 2.38 in H
  • Electrical Ratings: 0.24 A 115 VAC 60 Hz
  • Mounting Type: Panel
  • Series: EC-1
  • Sound Level: 21 dba
  • Temperature Rating: 140 deg f
  • Type: Automatic
  • Flow Rate: 2.5 gph
  • Outlet Size: 1/4 in
  • Shutoff Head: 33 ft
The EC-1 series is a new concept for mini pumps incorporating an improved noise reducing design and reliable solid-state switching technology. Easy to install brackets provide a quick and precise method to accurately position and secure both parts of the pump quickly. The two piece design allows the reservoir to be placed within the air handler while the pump-controller is located outside the air handler. The two components are connected via a convenient communications wire and suction tubing.
  • Features
  • Standards & Approvals
  • Includes
  • Application
Normally-closed relay rated at 8 A resistive 250 V alarm
Elastomeric mounting grommets on pump housing bracket
Elastomeric passive vibration isolator used to dampen pump vibration
For use in removing condensate from wall mount, ductless mini-split air conditioners up to 34000 Btu, used to remove condensate from fan coils and suspended ceiling air conditioners
3.3 ft communications cable (pump to reservoir)
176 deg F thermal protection
Clear reservoir for instant visual inspection of water level, float and filter
Hall effect on/off level sensors with high water safety sensor feature
Extra-large filter screen for longer intervals between cleaning
Multi-step drain hose adapter (1/2 in, 5/8 in, and 3/4 in)
Simple to open reservoir for easy maintenance
The pump can be installed above the air conditioner in a false ceiling, behind the wall mount air handler or in plastic conduit or line-set channel
The reservoir, featuring a clear tank, connects to the condensate drain hose and must be positioned flat and horizontal while the pump can be oriented in any position within 3.3 ft
3 ft suction lift
cCSAus Certified
Safety Switch, 3 x 5/32 in ID Suction Tubing, 8 in x 5/32 in ID Vent Tubing, 3 in x 1/2 in ID Drain Tubing and 5/32 in x 1/4 in ID Tubing Adapter
For removes condensate from ductless mini-split air conditioners and fan-coil equipment