Dimensions:
4-3/8 in H x 4 1/8 in W x 2 1/2 in D
-
Mounting Type:
Junction Box
-
Temperature Rating:
-40 to 130 deg f
-
Voltage Rating:
120/240
-
Amperage Rating:
3.7 to 7.4
-
Ignition Type:
Intermittent
-
Domestic/Import:
Domestic
The TRADELINE intermittent ignition oil primary control operates the oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat from the thermostat. Through a C554 Cad Cell Flame Sensor, the R8184 monitors the burner flame and shuts down the system on ignition failure or on flame failure during the run cycle. A light emitting diode (LED) on the terminal strip lights when the safety switch opens to provide safety shutdown indication. A manual reset button is provided to reset the safety switch after lockout. For convenience in system maintenance, the safety switch can be manually opened using a lever on the front of the control. Clock thermostats that power the clock through the primary control transformer will lose time during lockout unless backup batteries are installed.