if (this.Model.StructuredPageData.IsNotBlank() && (this.Model.StructuredPageData.IndexOf(availabilityKey) != -1 || this.Model.StructuredPageData.IndexOf(priceKey) != -1))
{
this.Model.StructuredPageData = string.Empty;
//}
}
Universal Automatic Make-Up Air Damper With Pressure Sensor Kit
BROAN MD6TU 6" UNIVERSAL AUTOMATIC MAKE-UP AIR DAMPER W/PRESSURE SENSOR
Kitchen Exhaust Ventilation Accessories
Brand:
}
Universal Automatic Make-Up Air Damper With Pressure Sensor Kit
3307825
MFG #: MD6TU
Product ID:3307825
Famous Supply
-
Dimensions:
9 in D in
-
Finish:
Galvanized
-
Type:
Universal
-
Suitable For Use With:
400 cfm Range Hood
-
Material:
24 ga Steel
Designed to provide the best technology to equalize pressure between indoors and outdoors, while providing effective ventilation for a cleaner, healthier home. Eliminate gases, smoke or particulates generated from naturally vented combustion devices like a fireplace or water heater. Only Broan® offers such a complete and simple solution for automatic and controlled fresh air into the home every time you turn on the range hood! This is an interlocked, synchronized system that installs easily and requires only low voltage wiring to the sensor. Perfect for new construction or retrofit into an existing home.
-
Features
-
Warranty
-
Standards & Approvals
-
Includes
-
Application
Broan® interlocked make-up air dampers provide outside air when required to keep the air in the home fresher by allowing the range hood to operate at optimum levels |
Universal design works with any Broan® range hood to balance indoor air pressure by providing interlocked make-up air without requiring a direct wire connection between the range hood and the damper |
Instead a sensor is attached to the exhaust duct to detect if the range hood is operating |
Slave dampers (MD6S, MD8S or MD10S) are interlocked to the main automatic or universal make-up air damper and open in unison for synchronized operation |
They close, along with the main damper, as soon as the range hood is powered off, slave dampers can be "ganged" together to provide a cost effective means to provide for higher volumes of make-up air |
Interlocked make-up air damper systems meet IRC code requirements for make-up air with range hoods over 400 cfm |
Interlocked make-up air systems avoid wasted energy associated with barometric solutions and do not let unwanted air into the home during heating or cooling activities so air pressure is equalized for a well-balanced environment |
Fresh air wall caps are required for use with make-up air dampers |
Also works with ULTRA and QT series fans if at least 80 cfm |
Includes
24 V 20VA Transformer |
2100-HVI Certified |
IRC Code M1503.4 |